- 1 -3226 Trunk Port FXO DoorphoneInstallation and User GuideAlgo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 www.algosolutions.comDocume
- 10 -Setting NameDTMF CodeDescription DefaultDoor ControlOpen Code **31 LL S… LL = length of string (00 to 04)S… = numeric string (e.g. **31016
- 11 -Setting NameDTMF CodeDescription DefaultSecurityMax Door Open **51 nn nn=00: 30 secnn=01: 2 minnn=02: 15 minnn=03: 30 minnn=04: 60 minnn=0
- 12 -CLID Character TableCode Char Code Char Code Char Code Char Code Char00 Space 20 4 40 H 60 \ 80 p01 ! 21 5 41 I 61 ] 81 q02 " 22 6 42 J 62
- 13 -Door or Gate Control BasicsDoor control contacts are provided from the Doorphone Controller and are typically used for door strike activation or
- 14 -Power SupplyThe Doorphone Controller provides an auxiliary 24 V 0.3 A power supply which is suitable for common types of door strikes. If more c
- 15 -Connections and LightsAuxiliary Dry Contact OutputsBoth the Doorphone Controller and Door Station provide a dry contact output for connection to
- 16 -Connection DetailsDoor Control (5 Position Removable Terminal Block)Relay NO Normally Open24V 0.3AC CommonNC Normally ClosedAuxiliary PowerPWR -
- 17 -SpecicationsTelephoneInterface Connect to analog telephone, FXO gateway, telephone system analog trunk portRing Voltage 65 Vrms ring voltage 20
- 18 -Weather ResistanceCSA/UL NEMA 3R weather resistant for outdoor locationsCall Button Backlit tactile silicon rubberInstallation Flush or surface
- 19 -Conguration ToolThe USB Conguration Tool is a Windows software alternative to the DTMF programming method described earlier in this Guide. To
- 2 -Important Safety NoticeThe 3226 Trunk Port FXO Doorphone is designed and tested to comply with EN 60950-1:2006 safety requirements.When the Doorp
- 20 -Algo Communication Products Ltd., Burnaby, BC Canada V5J 5L2 www.algosolutions.comRelated Algo Doorphone Products8028 SIP DoorphoneThe 8028 emu
- 3 -Table of ContentsSupport ...2FCC Compliance...2Impor
- 4 -IntroductionThe 3226 Trunk Port FXO Doorphone connects to an FXO port of a gateway device, loop start trunk port of a telephone system, or a trad
- 5 -Quick Install & TestThe 3226 Trunk Port FXO Doorphone is pre-congured for a typical installation. Programming is only required to change def
- 6 -Application BasicsThe 3226 architecture and digital link between the Door Station and Controller provides exible options using the auxiliary inp
- 7 -Anti-Door TamperA feature of the 3226 Doorphone is to ring the telephone(s) with a warning alert in the event a door is ajar due to tampering (su
- 8 -Basic Wiring Setup 24V 0.3A24VDC 0.6AUSB Configuration PortPower Input 24 V 0.6 ATelephone Jack. Connect to FXO Gateway, analog telephone, or
- 9 -Programming & CongurationThe 3226 Trunk Port FXO Doorphone may be programmed either by DTMF or through software using the USB connection on