The 3226 architecture and digital link between the Door Station and Controller
provides exible options using the auxiliary inputs and outputs. These are
some typical applications:
Cancel Ring When Door Opened
In a residential or warehouse installation it is not uncommon for the door to
be answered in person before the phone is answered. Either Door Station
or Control Unit inputs can be congured to cancel ring if the door is opened
before a call is answered. This requires a normally closed or normally open
contact to detect door open.
Trigger Door Bell from Door Station
When the Door Station call button is pressed, either (or both) the Door Station
or Control Unit dry contact output can be congured to activate a door bell or
auxiliary alerting system in addition to phone ring.
Trigger Door Station from External Button/Event
Either the Control Unit or Door Station can accept a dry contact closure to
activate the Doorphone as if the call button had been pressed. This could be
an external doorbell button, PIR detector, or some other system.
Cancel Door Open Relay once Door Opened
The door opening control can be set for activation (using the `Open Code’) up
to 30 seconds (set by the `Relay Time’ setting) to allow sufcient time for entry.
For security, the 3226 Doorphone can be congured to cancel Door Opening
once the door is opened to prevent “tailgating” by unauthorized personnel.
Unlock Door Indenitely until Canceled
The door opening control can be set to unlock indenitely (using the `Latch
Open Code’) until canceled (using the `Release Code’) that locks it again. This
allows an entrance to be used repeatedly for a period of time without requiring
multiple activations of the door control relay.